Evo ovo su parametri:).Hvala
n-8-1 Type pellet
n-8-1-01 Load pelet 00
n-8-2 Type Chimney
n-8-2-01 Ecxaust Chimney 03
n-8-3 Bank Data 00
n-8-4-06 Differen Off Auto 04.0c
n-8-4-07 Del-off Auto 02'
n-8-6-01 Minutes Time Out 22'
n-8-6-02 Minuti Start 02'
n-8-9-03 Cadence Cleaning 25'
n-8-6-04 Auger Light 1.6'
n-8-6-05 Coclea Start 1.6''
n-8-6-06 Coclea Power1 1.5''
n-8-6-07 Coclea Power2 2.2''
n-8-6-08 Coclea Power3 3.3''
n-8-6-09 Coclea Power4 4.5''
n-8-6-10 Coclea Power5 6.0''
n-8-6-11 Delay Alarm 30''
n-8-6-12 Duration Cleaning 45'
n-8-6-13 Threshol Minimum 44c
n-8-6-14 Threshol Maximum 220c
n-8-6-15 Thresol Blower 60c
n-8-6-16 Exhaust En-Start 2250
n-8-6-17 Exhaust Engi-Avv 2650
n-8-6-18 Exhaust Engine1 1750
n-8-6-19 Exhaust Engine2 1950
n-8-6-20 Exhaust Engine3 2150
n-8-6-21 Exhaust Engine4 2350
n-8-6-22 Exhaust Engine5 2700
n-8-6-24 Time Breaking 0.2''
n-8-6-25 Treshol Pump 47c
n-8-6-26 Exclued Pressure ON
n-8-6-27 Treshol Pression 2.5b
n-8-6-28 Treshol OFF 70c
n-8-6-30 Auger Cleaning 0.5''
n-8-6-31 Speed Blow1 130u
n-8-6-32 speed Blow2 150u
n-8-6-33 Speed Blow3 170u
n-8-6-34 Speed Blow4 185u
n-8-6-35 Speed Blow5 225u
Pec se nalazi u podrumu zgrade a stan (60m2)je na prvom spratu, znaci visinska razlika je oko 8m.Instaliran je jos jedan ekspanzioni sud od 12l.Termostat je wireless i radi bez problema, pali i gasi pec na zadatoj temp. u prostoriji (22 stepena sa tolerancijom 0.2 stepena).
Temperatura vode u kotlu je podesena na 60 stepeni.STAND-By mode je ukljucen tako da se pec naizmenicno pali i gasi po potrebi ali gotovo nikako pec ne ide u MODULAT rezim.Jednostavno kada postigne temreaturu aktivira STAND-BY rezim i onda pocne cuveno hladjenje peci WAIT COOLING.
Probao sam sa varijantom da iskljucimSTAND-BY rezim ali onda pec radi u MODULAT rezimu i kada joj termostat ne daje komandu odnosno kada je zadata temperatura vec postignuta.
Commo Compact 22,57 kW